Home > Products > Electrical Products > HAPL automatic gluing series
Back to Products   >

HAPL-Ⅱ series Automatic Assembly Line Equipment

Performance

High safety

On the surface is low load wound-type electric heating tube, so the surface temperature is below 350 ℃, which eliminates combustion and explosion hazards;

Electric strong exhaust ventilation keeps the concentration of dangerous gas inside the preheating and curing heating rooms within the safe range;

Strong exhaust fan/circulating fan/heating power supply are under interlocking control.

Low energy consumption:

lifting door of the heating chamber is sealed, so heat does not overflow

The surface temperature rise ≤indoor temperture+15℃。

Smooth operation

Mechanical positioning is accurate and reliable

Double speed chain for bearing, chain transmission for transmission, transmission and bearing are separated, these are patented technology

Long life service

Part of the heating tube has three years of warranty.

Heating room is without transmission mechanism or electronic positioning device, no pneumatic blocking mechanism and the original copy, so the operation is stable and slow aging after long-term use with little maintenance,

Quality Assurance

Preheating temperature and curing temperature are controlled separately.

Horizontal or vertical type of air blast are free to choose for your product.

The temperature uniformity is enhanced to be within ±5℃ range to be the guardian for the quality of your products.

Control System

Configuration software, computer distributed control, PLC touch screen control, field visualization and mobile remote access.

Main technical parameters of HAPL-Ⅱ series Automatic Assembly Line Equipment

ParameterHAPL-Ⅱ
Dimension of tooling plate  (length×width)mm400*400
Glue pouring beat (min/ plate)12
Output (disk /h)5
Size of preheating chamber (width * depth * height)mm500×2100×420
Preheating operating temperature (℃)Indoor temperature--90
Preheating time(min)30
Preheating power (kw)6
Total length of preheating section line (mm)3300
Vacuum filling size (width x length)mm500*1600
Product transition modeAir lift/horizontal ferry/jacking translation
Curing room size (width x depth x height)mm450×4500×420
Curing operating temperature (℃)Indoor temperature--120
curing time (min)120
Curing power (kw)12
The total length of the curing line (mm)5000
Voltage/Frequency (V/ Hz)3-380/50
precision of temperature control (℃)±1
Temperature uniformity(%)±2.5
Temperature rise of heating chamber’s surface≤indoor temperature+15℃
Type of coolingNatural cooling/fan cooling
Heating modeElectric heating
Transmission modeSpeed chain
Transmission controlCycle-base+automated program
Tooling plate positioningMechanical + hook (accurate and safe)
Gate opening modePneumatic lifting
Electrical controlPLC+ human-machine interface/configuration software + remote access
Total installed power27
 Site occupation (length x width)mm6000×3000

Note: Non-standard product can be designed and manufactured in accordance with the requirements of the user;

(2) tooling plate size is decided by the size and quantity of the product.


Product images