Home > Products > Electrical Products > HAPL automatic gluing series
Back to Products   >

HAPL-Ⅲ series Automatic Assembly Line Equipment

Performance

High safety

On the surface is low load wound-type electric heating tube, so the surface temperature is below 350 ℃, which eliminate combustion and explosion hazards;

Electric strong exhaust ventilation keeps the concentration of dangerous gas in the preheating and curing heating rooms within the safe range;

Strong exhaust fan/circulating fan/heating power supply are under interlocking control.

Low energy consumption:

lifting door of the heating chamber is sealed, so heat does not overflow

The surface temperature rise ≤indoor temperture+15℃。

Smooth operation

Mechanical positioning is accurate and reliable

Double speed chain for bearing, chain transmission for transmission, transmission and bearing are separated, these are patented technology

Long life service

Part of the heating tube has three years of warranty.

Heating room is without transmission mechanism or electronic positioning device, no pneumatic blocking mechanism and the original copy, so the operation is stable and slow aging after long-term use with little maintenance


Quality Assurance

Temperature control at preheating single temperature zone 

Horizontal or vertical type of air blast are free to choose for your product.

The temperature uniformity is enhanced to be within ±5℃ range to be the guardian for the quality of your products.

Control System

Configuration software, computer distributed control, PLC touch screen control, field visualization, mobile remote access.

Main technical parameters of HAPL-Ⅲ series Automatic Assembly Line Equipment

ParameterHAPL-Ⅲ 
Dimension of tooling plate   (length×width)mm 700*700
Glue pouring beat (min/ plate)10
Output (disk /h)6
Dimension of preheating chamber (width * depth * height)mm850×5200×400
Preheating operating temperature(℃)Indoor temperature--200
Preheating time(min)60
Preheating power(kw)36
Total length of preheating section line (mm)6500
Vacuum glue pouring size (width x length)mm850*2500
Product transition modeAir lift/horizontal ferry/jacking translation
Curing room size (width x length x height)mm850×16200×400
Curing operating temperature (three zones)℃indoor temperature --9090-135135
Curing time (three stages)(min)16040160
Curing power (kw)10827108
The total length of the curing line (mm)18400×2
Operating voltage/Frequency (V/ Hz)3-380/50
Precision of temperature control (℃)±1
Temperature uniformity (%)±2.5
Temperature rise of heating chamber’s surface≤indoor temperature+15℃
Type of coolingNatural cooling/fan cooling
Type of heatingElectric heating
Transmission modeSpeed chain
Transmission controlCycle-based+ automated program
Tooling plate positioningMechanical + hook (accurate and safe)
Door opening modePneumatic lifting
Electric controlPLC+ human-machine interface/configuration software + remote access
Total installed power320
Site occupation (length x width)mm21000×8000

Note: Non-standard product can be designed and manufactured in accordance with the requirements of the user;

(2) tooling plate size is decided by the size and quantity of the product.


Product images